Oil immersed type 400kv power transformer
Payment Type: | L/C,T/T |
---|---|
Min. Order: | 1 Set/Sets |
Delivery Time: | 30 Days |
Packaging: | wooden case |
---|---|
Brand: | SHFE |
Place of Origin: | Shanghai, China (Mainland) |
Supply Ability: | 400 Set/Sets per Month |
Basic Info
Model No.: Y/Delta, Y/Y, Delta/Y
Product Description
Capacity (kVA) | Voltage Combination | Connection Symbol | No-load loss (W) | Load loss (W) (75°C) | Impedance voltage (%)
| No-load current (%) | ||
HV (kV) | Tapping range of HV | LV (kV) | ||||||
30 | 6,10,11 | ±5%,±2×2.5% | 0.4 | Yyn0 Dyn11 | 100 | 600 | 4.0 | 1.7 |
50 | 130 | 870 | 1.6 | |||||
63 | 150 | 1040 | 1.5 | |||||
80 | 180 | 1250 | 1.4 | |||||
100 | 200 | 1500 | 1.3 | |||||
125 | 240 | 1800 | 1.2 | |||||
160 | 280 | 2200 | 1.1 | |||||
200 | 340 | 2600 | 1 | |||||
250 | 400 | 3050 | 0.9 | |||||
315 | 480 | 3650 | 0.9 | |||||
400 | 570 | 4300 | 0.8 | |||||
500 | 680 | 5100 | 0.8 | |||||
630 | 810 | 6200 | 4.5 | 0.7 | ||||
800 | 980 | 7500 | 0.6 | |||||
1000 | 1160 | 10300 | 0.55 | |||||
1250 | 1360 | 12000 | 0.5 | |||||
1600 | 1640 | 14500 | 0.45 | |||||
2000 | 1940 | 18500 | 5.5 | 0.4 | ||||
2500 | 2300 | 20500 | 0.4 |
Capacity (kVA) | Voltage | Connection group | No-load loss (W) | Load loss (W) (75°C) | Impedance voltage (%) | No-load current (%) | ||
Primary (kV) | Tapping range (%) | Secondary (kV) | ||||||
50 | 35 | ±5% | 3.15 6.3 10.5 | Yyn0 | 6.5 | 1210 | 6.5 | 2.0 |
100 | 305 | 2020 | 1.80 | |||||
125 | 340 | 2380 | 1.75 | |||||
160 | 360 | 2830 | 1.65 | |||||
200 | 430 | 3300 | 1.55 | |||||
250 | 510 | 3950 | 1.40 | |||||
315 | 610 | 4750 | 1.40 | |||||
400 | 735 | 5750 | 1.30 | |||||
500 | 870 | 6900 | 1.30 | |||||
630 | 1040 | 8250 | 1.25 | |||||
800 | 1250 | 9900 | 1.05 | |||||
1000 | 1480 | 12150 | 1.00 | |||||
1250 | 1760 | 14600 | 0.90 | |||||
1600 | 2130 | 17500 | 0.85 | |||||
2000 | 2500 | 20680 | 0.75 | |||||
2500 | 2975 | 24500 | 0.75 |
66kV Two-Winding Power Transformer With NVTC/OLTC | |||||||
Rated Capacity (kVA) | Rated Voltage (kV) | Vector Group | Losses (W) | Impedance Voltage (%) | |||
HV | Tapping Range | LV | No load | On load | |||
630 | 63 66 69 | ±5% | 6.3 6.6 10.5 11 | Yd11 | 1360 | 7560 | 8.0 |
800 | 1620 | 8830 | |||||
1000 | 1920 | 10440 | |||||
1250 | 2260 | 12340 | |||||
1600 | 2720 | 14850 | |||||
2000 | 3200 | 17550 | |||||
2500 | 3760 | 20700 | |||||
3150 | YNd11 | 4480 | 24300 | ||||
4000 | 5280 | 28800 | |||||
5000 | 6240 | 32400 | |||||
6300 | ±2×2.5% | 8000 | 36000 | 9.0 | |||
8000 | 9600 | 42750 | |||||
10000 | 11360 | 50400 | |||||
12500 | 13360 | 59850 | |||||
16000 | 16080 | 73530 | |||||
20000 | 19040 | 89100 | |||||
25000 | 22480 | 105300 | |||||
31500 | 26720 | 126900 | |||||
40000 | 32000 | 148950 | |||||
50000 | 37760 | 184500 | |||||
63000 | 44880 | 222300 |
110kV Two-Winding Power Transformer With NVTC/OLTC | |||||||
Rated Capacity (kVA) | Rated Voltage (kV) | Vector Group | Losses (W) | Impedance Voltage (%) | |||
HV | Tapping Range | LV | No load | On load | |||
6300 | 110 121 | ±2×2.5% | 6.3 6.6 10.5 11 | YNd11 | 8000 | 36900 | 10.5 |
8000 | 9600 | 45000 | |||||
10000 | 11200 | 53100 | |||||
12500 | 13200 | 63000 | |||||
16000 | 16000 | 77400 | |||||
20000 | 19000 | 93600 | |||||
25000 | 22400 | 110700 | |||||
31500 | 26700 | 133200 | |||||
40000 | 31800 | 156600 | |||||
50000 | 37600 | 194400 | |||||
63000 | 44600 | 234000 |
110kV Three-Winding Power Transformer With NVTC/OLTC | ||||||||
Rated Capacity (kVA) | Rated Voltage (kV) | Vector Group | Losses (W) | Impedance Voltage (%) | ||||
HV | Tapping Range | LV | No load | On load | Step Up | Step Down | ||
6300 | 110 ±2×2.5% 121 ±2×2.5% | 35 38.5 ±2×2.5% | 6.3 6.6 10.5 11 | YNyn0d11 | 9600 | 47700 | HV-MV 17-18 HV-LV 10.5 MV-LV 6.5 | HV-MV 10.5 HV-LV 17-18 MV-LV 6.5 |
8000 | 11500 | 56700 | ||||||
10000 | 13600 | 66600 | ||||||
12500 | 16000 | 78300 | ||||||
16000 | 19300 | 95400 | ||||||
20000 | 22800 | 112500 | ||||||
25000 | 27000 | 133200 | ||||||
31500 | 32000 | 157500 | ||||||
40000 | 38200 | 189000 | ||||||
50000 | 45200 | 225000 | ||||||
63000 | 53600 | 270000 |
220kV Two-Winding Power Transformer With NVTC/OLTC | ||||||
Rated Capacity (kVA) | Rated Voltage (kV) | Vector Group | Losses (W) | Impedance Voltage (%) | ||
HV | LV | No load | On load | |||
31500 | 220 ±2×2.5% | 6.3 | YNd11 | 29000 | 135000 | 12-14 |
40000 | 6.6 | 35000 | 158000 | |||
50000 | 10.5 | 41000 | 189000 | |||
63000 | 11 | 49000 | 221000 | |||
90000 | 10.5 | 65000 | 288000 | |||
120000 | 13.8 11 | 80000 | 347000 | |||
150000 | 11 | 96000 | 405000 | |||
180000 | 13.8 | 109000 | 459000 | |||
240000 | 15.75 | 136000 | 567000 | |||
300000 | 15.75 | 160000 | 675000 | |||
360000 | 18 | 184000 | 774000 |
220kV Three-Winding Power Transformer With NVTC/OLTC | |||||||||
Rated Capacity (kVA) | Rated Voltage (kV) | Vector Group | Losses (W) | Impedance Voltage (%) | Capacity Arrange (%) | ||||
HV | MV | LV | No load | On load | Step Up | Step Down | |||
31500 | 220 ±2×2.5% | 69 121 | 6.3 6.6 | YNyn0d11 | 34000 | 162000 | HV-MV 22-24 HV-LV 12-14 MV-LV 7-9 | HV-MV 12-14 HV-LV 22-24 MV-LV 7-9 | 100/100/100 100/50/100 100/100/50 |
40000 | 10.5 11 | 40000 | 189000 | ||||||
50000 | 35 | 48000 | 225000 | ||||||
63000 | 38.5 | 56000 | 261000 | ||||||
90000 | 10.5 11 13.8 | 73000 | 351000 | ||||||
120000 | 35 38.5 | 90000 | 432000 | ||||||
150000 | 11 13.8 | 106000 | 513000 | ||||||
180000 | 15.75 35 | 121000 | 585000 | ||||||
240000 | 38.5 | 149000 | 720000 |






Contact us if you need more details on 400kv Power Transformer. We are ready to answer your questions on packaging, logistics, certification or any other aspects about 400kv Transformer、400kv Power Transformer. If these products fail to match your need, please contact us and we would like to provide relevant information.