Three phase oil immersed 63kV 69kV 40mva transformer
Three phase oil immersed 63kV 69kV 40mva transformer
Payment Type: | L/C,T/T |
---|---|
Min. Order: | 1 Set/Sets |
Delivery Time: | 30 Days |
Packaging: | wooden case |
---|---|
Brand: | SHFE |
Place of Origin: | Shanghai, China (Mainland) |
Supply Ability: | 400 Set/Sets per Month |
Basic Info
Model No.: Y/Delta, Y/Y, Delta/Y
Product Description
Specifications Low loss
Long usage life
IEC standards
Over 30 year
Original equipments manufacturer
1.Application 10kV-220kV transformers are mainly made of iron core and windings which are placed in the oil tank that filled with insulating oil. It is mainly used for power plant, power transmission and distribution station as the equipment of power transmission. 2.Type and Rating .Product types: Single phase or three phases Two windings or three windings On-load or no-load voltage tap changer, Autotransformer, Natural cooling forced cooling or oil cooling, etc. .Capacity range: 50kVA-650MVA .Frequency; 50/60Hz 3.Standard IEC 60076-1:2000, IEC 60076-2:1993, IEC 60076-3:2000, IEC 60076-5:2006, IEC 60137:2003; ANSI, IEEE, AS, etc 4.Operating Condition Suitable for indoor and outdoor application Ambient temperature: +400C--300C Relative humidity: ambient air relative humidity should be below 93%. .Altitude:≤1000m .Max wind speed: ≤35 m/s .Earthquake acceleration: horizontal acceleration≤0.3g vertical acceleration≤0.15g .Special conditions: customized products are available. 5.Performance
6. INSULATION LEVELS
AUXILIARY SUPPLIES Equipment generally rated for the following auxiliary power supplies: (a) Cooler control circuits: 220V, 240 V, single phase, 50Hz (b) Tap changer control: 220V, 240 V, single phase, 50Hz (c) Cooling fan motors: 380V, 415 V, three phase, 50Hz (d) Tap changer motor: 380V, 415 V, three phase, 50Hz ROUTINE TEST to IEC 60076 (to be done during acceptance testing at factory) • Measurement of winding resistance • Ratio test • Vector group • Separate source voltage withstand test • Induced over-voltage • Insulation resistance • Oil leakage test on fully assembled Transformer for 12 hours • Measurement of impedance voltage • Magnetic balance • Measurement of no-load loss and current • Measurement of load loss (at normal & extreme taps) • Tests on on-load tap-changer • Tests on on-load tap-changer remote control panel • Efficiency at 50%, 75%, 100% loading at unity p.f and rated terminal voltage (Corrected to 75C) • Lightning impulse withstand test Type Tests to IEC 60076 (to be done during acceptance testing at factory) • Temperature rise test – To be performed on one unit during acceptance testing. Lightning Impulse Withstand Test is already listed under Routine Tests as per IEC 60076. Test Facility
Contact us if you need more details on 40 Mva Transformer. We are ready to answer your questions on packaging, logistics, certification or any other aspects about 40 Mva Transformer、40 Mva Transformer. If these products fail to match your need, please contact us and we would like to provide relevant information.
Long usage life
IEC standards
Over 30 year
Original equipments manufacturer
1.Application 10kV-220kV transformers are mainly made of iron core and windings which are placed in the oil tank that filled with insulating oil. It is mainly used for power plant, power transmission and distribution station as the equipment of power transmission. 2.Type and Rating .Product types: Single phase or three phases Two windings or three windings On-load or no-load voltage tap changer, Autotransformer, Natural cooling forced cooling or oil cooling, etc. .Capacity range: 50kVA-650MVA .Frequency; 50/60Hz 3.Standard IEC 60076-1:2000, IEC 60076-2:1993, IEC 60076-3:2000, IEC 60076-5:2006, IEC 60137:2003; ANSI, IEEE, AS, etc 4.Operating Condition Suitable for indoor and outdoor application Ambient temperature: +400C--300C Relative humidity: ambient air relative humidity should be below 93%. .Altitude:≤1000m .Max wind speed: ≤35 m/s .Earthquake acceleration: horizontal acceleration≤0.3g vertical acceleration≤0.15g .Special conditions: customized products are available. 5.Performance
66kV Two-Winding Power Transformer With NVTC/OLTC | |||||||
Rated Capacity (kVA) | Rated Voltage (kV) | Vector Group | Losses (W) | Impedance Voltage (%) | |||
HV | Tapping Range | LV | No load | On load | |||
630 | 63 66 69 | ±5% | 6.3 6.6 10.5 11 | Yd11 | 1360 | 7560 | 8.0 |
800 | 1620 | 8830 | |||||
1000 | 1920 | 10440 | |||||
1250 | 2260 | 12340 | |||||
1600 | 2720 | 14850 | |||||
2000 | 3200 | 17550 | |||||
2500 | 3760 | 20700 | |||||
3150 | YNd11 | 4480 | 24300 | ||||
4000 | 5280 | 28800 | |||||
5000 | 6240 | 32400 | |||||
6300 | ±2×2.5% | 8000 | 36000 | 9.0 | |||
8000 | 9600 | 42750 | |||||
10000 | 11360 | 50400 | |||||
12500 | 13360 | 59850 | |||||
16000 | 16080 | 73530 | |||||
20000 | 19040 | 89100 | |||||
25000 | 22480 | 105300 | |||||
31500 | 26720 | 126900 | |||||
40000 | 32000 | 148950 | |||||
50000 | 37760 | 184500 | |||||
63000 | 44880 | 222300 |
Nominal system voltage
(kV, rms) | Highest system voltage
(kV, rms) | Lightning Impulse withstand voltage, dry (kV, peak) | Power frequency withstand voltage, wet (kV, rms) |
33 | 36 | 200 | 95 |
132 | 145 | 650/750 (internal/external) | 275/325(internal/external) |
Contact us if you need more details on 40 Mva Transformer. We are ready to answer your questions on packaging, logistics, certification or any other aspects about 40 Mva Transformer、40 Mva Transformer. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : Distribution Transformers > 66,110,220kV Distribution Transformers
Other Products
Hot Products
Moulded Case Circuit Breaker, MCCBIntelligent Universal Circuit Breaker(ACB)3000kg Block ice machineAir load break switchVacuum circuit breaker 15kvMetal clad cubicle switchboardMedium voltage metal clad 15 kv switchgearLow voltage generator paralleling switchgearMeta-clad withdrawable type ht switchgearGTM2L 4 pole earth leakage circuit breakerThree phase copper winding wound core low loss 35kv 6.3mva transformerGTM2L earth leakage circuit breakerThree phase oil immersed type copper winding wound core low loss 15 mva 20kv transformer11kv 415v dry type power transformerOil immersed type 400kv power transformerFlake ice machine for Cocktail