66kV Oil-immersed Power Transformer

66kV Oil-immersed Power Transformer

    Payment Type: L/C,T/T
    Min. Order: 2 Set/Sets
    Delivery Time: 60 Days
    Packaging: Bare
    Brand: SHFE
    Place of Origin: Shanghai, China (Mainland)
    Supply Ability: 4 Set/Sets per Month

Basic Info

Model No.: SF, SZ

Product Description

Specifications Economic or deluxe solution optional

Better cost performance

IEC Standards Criteria

New factory for better price

NVTC/ OLTC

REFERENCES   ISO 1461: Hot dip galvanized coatings on fabricated iron and steel articles – Specifications and test methods. IEC 60076: Power transformers. IEC 60044: Instrument transformers. IEC 60296: Specification for unused mineral insulating oil for transformers and Switchgear. IEC 60354: Loading guide for oil – immersed power transformers. IEC 60214: Tap-changers - Part 1: Performance requirements and test methods, Part 2: Application guide. IEC 60512: Connectors for electronic equipment.   Performance
66kV Two-Winding Power Transformer With NVTC/OLTC
Rated Capacity (kVA) Rated Voltage (kV) Vector Group Losses (W)

Impedance Voltage

(%)

HV Tapping Range LV No load On load
630 63 66 69 ±5% 6.3 6.6 10.5 11 Yd11 1360 7560 8.0
800 1620 8830
1000 1920 10440
1250 2260 12340
1600 2720 14850
2000 3200 17550
2500 3760 20700
3150 YNd11 4480 24300
4000 5280 28800
5000 6240 32400
6300 ±2×2.5% 8000 36000 9.0
8000 9600 42750
10000 11360 50400
12500 13360 59850
16000 16080 73530
20000 19040 89100
25000 22480 105300
31500 26720 126900
40000 32000 148950
50000 37760 184500
63000 44880 222300
     INSULATION LEVELS

Nominal system voltage

 

(kV,   rms)

Highest system voltage

 

(kV,   rms)

Lightning Impulse withstand voltage, dry

(kV,   peak)

Power frequency withstand voltage, wet

(kV,   rms)

33

36

200

95

132

145

650/750 (internal/external)

275/325 (internal/external)

  AUXILIARY SUPPLIES Equipment generally rated for the following auxiliary power supplies:   (a)          Cooler control circuits:          220V, 240 V, single phase, 50Hz (b)         Tap changer control:              220V, 240 V, single phase, 50Hz (c)          Cooling fan motors:               380V, 415 V, three phase, 50Hz (d)         Tap changer motor:               380V, 415 V, three phase, 50Hz    ROUTINE TEST to IEC 60076 (to be done during acceptance testing at factory) • Measurement of winding resistance • Ratio test • Vector group • Separate source voltage withstand test • Induced over-voltage • Insulation resistance • Oil leakage test on fully assembled Transformer for 12 hours • Measurement of impedance voltage • Magnetic balance • Measurement of no-load loss and current • Measurement of load loss (at normal & extreme taps) • Tests on on-load tap-changer • Tests on on-load tap-changer remote control panel • Efficiency at 50%, 75%, 100% loading at unity p.f and rated terminal voltage (Corrected to 75C) • Lightning impulse withstand test   Type Tests to IEC 60076 (to be done during acceptance testing at factory)   • Temperature rise test – To be performed on one unit during acceptance testing. Lightning Impulse Withstand Test is already listed under Routine Tests as per IEC 60076.   Test Facility

Contact us if you need more details on 66kv Power Transformer. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Power Transformer、66kv Oil Transformer. If these products fail to match your need, please contact us and we would like to provide relevant information.