12kv/24kv SF6 load break switch
Payment Type: | L/C,T/T |
---|---|
Min. Order: | 1 Set/Sets |
Delivery Time: | 30 Days |
Packaging: | Wooden case |
---|---|
Brand: | SHFE CHFE |
Place of Origin: | China (Mainland) |
Supply Ability: | 500 Set/Sets per Month |
Basic Info
Model No.: FLN series
Product Description
1.Siemens cooperative partener
2.ISO9000 Certificate
3.30 years manufacture
Description FLN36 Indoor Load Break Switch protect electric device and control it.The protection features of Fuse series electricity match with Transformer,which is applicable to loop net power supply unit. It, a kind of rotate load switch of double cracks using air SF6 as isolation and extinguishing medium,applies to the usage of power distribution system of 24kv. Every switch is permanently sealed after charging 0.4bar of the air SF6.It doesmt matter if switch is installed vertically or horizontally. The typical installation inside RMU is the way to install steel lattice between cable chamber and bus room. This method separate bus and cable joint ,which matches with the strictest demands operting. If circuit error happens that makes exaggerate current so that switch inside fires inside, there is a structural weak spot,which would be pushed and then the gate over the switch will open to lead the air out. Using environmental conditions , a. ambient air temperature, upper limit+40, lower-15 b. daily average level less than 35 c. daily average level of relative temperature should less than 95%,monthly average level should less than 90% d. daily average vapour tension less than 2.2×10-3Mpa,monthly less than 1.8×10-3MPa e. elevation,<1000m f. Amplitude, The earthquake intensity does not exceed 8 degrees g. no water ,frost,condensation, or danger of flammability&explosion,no chamistry rusty or violent exercise Technical Data
Item | Unit | FLN36-12D | FLRN36-12D | |
Rated voltage | kV | 12 | 12 | |
Rated current | A | 630 | 125 | |
Rated frequency | Hz | 50 | 50 | |
Rated short-time withstand current of switch/rated continuous time of short-circuit | kA/s | 20/3 | ||
Rated short-time withstand current of earthing switch/rated continuous time of short-circuit | kA/s | 20/2 | ||
Rated peak withstand current and rated short-circuit making current | kA | 50 | 125 (anticipated) | |
Rated breaking current | Breaking current of active load | A | 630 | |
Breaking current of closed loop | A | 630 | ||
5% rated breaking current of active load | A | 31.5 | ||
Cable-charging breaking current | A | 10 | ||
Breaking capacity of no-load transformer | kVA | 1250 | 1250 | |
Breaking transfer current | A | 1700 | ||
Prospective short-circuit breaking current | kA | 50 | ||
Rated insulation level | 1 min power frequecny withstand voltage, phase-to-phase, to earth/break | kV | 42/48 | 42/48 |
Lighting impulse withstand voltage, phase-to-phase, to earth/break | kV | 75/85 | 75/85 | |
Mechanical life | 2000 | 2000 | ||
Rated pressure of SF6 gas (gauge pressure at 20°C) | Mpa | 0.04~0.05 | 0.04~0.05 |
Contact us if you need more details on Sf6 Load Break Switch. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Sf6 Load Break Switch、Sf6 Load Break Switch. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : Circuit Breakers & Switches > Load Break Switch