Electrical Power Transformer Station
Electrical Power Transformer Station
Payment Type: | L/C,T/T |
---|---|
Min. Order: | 1 Set/Sets |
Delivery Time: | 25 Days |
Packaging: | Wooden case |
---|---|
Brand: | SHFE |
Place of Origin: | Shanghai, China (Mainland) |
Supply Ability: | 50 Set/Sets per Month |
Basic Info
Model No.: YB-12~40.5
Product Description
Specifications Electrical Transformer Station,Power Transformer Station
1.High:7.2kV~40.5kV
2.Low:0.4kV~12kV
3.50~20000kVA
4.European type
Electrical Transformer Station, Power Transformer Station Integrates high voltage electric equipments, transformers, and low voltage electric equipments into one box or house. Suitable for business center, resedential district, industrial and mining enterprises, hospital, school, airport, bus station, port and subway, etc. Service Condition 1.Altitude: <=1000m 2.Maximal ambient temperature: +40'C 3.Minimal ambient temperature: -25'C 4.Average temperature in 24 hours: <=35'C 5.Air velocity: <=35m/s 6.Relative humidity: daily average <=95%, monthly average <=90% 7.Horizontal acceleration of earthquake: <=0.4m/s2 8.Vertical acceleration of earthquake: <=0.2m/s2 9.No fire, explosion, severe dirtiness, chemical corrosion or excessive vibration. Special condition subjects to users Standard GB/T17467 SD320 Feature 1.Electrical Power Transformer Station is composed of high voltage unit, low voltage unit, relay protection unit and transformer unit. Small volume, reduced cost, reliability, maintainness free and transportability. 2.The casing is made of aluminium alloy plate, stainless steel plate, steel plate or composite board. Aluminium alloy plate is treated by anodic oxidation to enhance anticorrosion and intensity. Steel component is treated by bonderizing. 3.Thermal insulation material, ventilating fan, air conditioner and automatic controller are employed to keep required temperature and humidity inside the Substation. 4.Oil-immersed (S9, S11, S13, etc.) or dry-type (SCB10, etc.) transformers are optional. In the case of oil-immersed transformer, railings instead of enclosed casing are installed to reinforce cooling. Outer covering is applied for dry-type transformer. 5.Interlocking device prevents misoperation. 6.AC power supply panel, DC power supply panel, signal panel, protection panel, RTU, carrier machine or optical fiber terminal are installed in relay protection unit. 7.Transformer can be easily pushed in or pulled out from both sides through optional tracks in the unit. YB-12, YB-40.5 Electrical Power Transformer Station
Parameters of customized products subject to users Contact us if you need more details on Transformer Station. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Power Transformer Station、Electrical Transformer Station. If these products fail to match your need, please contact us and we would like to provide relevant information.
1.High:7.2kV~40.5kV
2.Low:0.4kV~12kV
3.50~20000kVA
4.European type
Electrical Transformer Station, Power Transformer Station Integrates high voltage electric equipments, transformers, and low voltage electric equipments into one box or house. Suitable for business center, resedential district, industrial and mining enterprises, hospital, school, airport, bus station, port and subway, etc. Service Condition 1.Altitude: <=1000m 2.Maximal ambient temperature: +40'C 3.Minimal ambient temperature: -25'C 4.Average temperature in 24 hours: <=35'C 5.Air velocity: <=35m/s 6.Relative humidity: daily average <=95%, monthly average <=90% 7.Horizontal acceleration of earthquake: <=0.4m/s2 8.Vertical acceleration of earthquake: <=0.2m/s2 9.No fire, explosion, severe dirtiness, chemical corrosion or excessive vibration. Special condition subjects to users Standard GB/T17467 SD320 Feature 1.Electrical Power Transformer Station is composed of high voltage unit, low voltage unit, relay protection unit and transformer unit. Small volume, reduced cost, reliability, maintainness free and transportability. 2.The casing is made of aluminium alloy plate, stainless steel plate, steel plate or composite board. Aluminium alloy plate is treated by anodic oxidation to enhance anticorrosion and intensity. Steel component is treated by bonderizing. 3.Thermal insulation material, ventilating fan, air conditioner and automatic controller are employed to keep required temperature and humidity inside the Substation. 4.Oil-immersed (S9, S11, S13, etc.) or dry-type (SCB10, etc.) transformers are optional. In the case of oil-immersed transformer, railings instead of enclosed casing are installed to reinforce cooling. Outer covering is applied for dry-type transformer. 5.Interlocking device prevents misoperation. 6.AC power supply panel, DC power supply panel, signal panel, protection panel, RTU, carrier machine or optical fiber terminal are installed in relay protection unit. 7.Transformer can be easily pushed in or pulled out from both sides through optional tracks in the unit. YB-12, YB-40.5 Electrical Power Transformer Station
Model | Rated voltage (kV) | Capacity (kVA) | |
High | Low | ||
YB-12 | 7.2, 12 | 0.4 | Horizontal layout: 200~1250 |
Vertical layout: 50~400 | |||
YB-40.5 | 40.5 | 0.4, 12 | 50~20000 |
Product Categories : Outdoor Substations > Other Outdoor Substations
Premium Related Products
Other Products
Hot Products
Moulded Case Circuit Breaker, MCCBIntelligent Universal Circuit Breaker(ACB)3000kg Block ice machineAir load break switchVacuum circuit breaker 15kvMetal clad cubicle switchboardMedium voltage metal clad 15 kv switchgearLow voltage generator paralleling switchgearMeta-clad withdrawable type ht switchgearGTM2L 4 pole earth leakage circuit breakerThree phase copper winding wound core low loss 35kv 6.3mva transformerGTM2L earth leakage circuit breakerThree phase oil immersed type copper winding wound core low loss 15 mva 20kv transformer11kv 415v dry type power transformerOil immersed type 400kv power transformerFlake ice machine for Cocktail