11kv/24kv/33kv electrical switchgear and control panel
Home > Products > Switchboards & Switchgears > Other Switchboards Switchgears > 11kv/24kv/33kv electrical switchgear and control panel

11kv/24kv/33kv electrical switchgear and control panel

    Payment Type: L/C,T/T
    Min. Order: 1 Set/Sets
    Delivery Time: 25 Days
    Packaging: wooden case or packaged
    Brand: CHFE
    Place of Origin: Shanghai, China (Mainland)
    Supply Ability: 500 Set/Sets per Month power switchgear

Basic Info

Model No.: HXGN ,SM6 ,RM6 ,SF6 Ring Main Unit

Product Description

Specifications Switchegear:

1.Easy installation and maintenance-free

2.Full-sealed&all insulated

3.Top ten Switchgear manufacutre&ISO9001

1.Feautre and benefits: 1.7kv to 36kv are available  2. All insulated and full-sealed  3.Compact and modular design  4, Flexible and smart   5 .Ease of  installation and maintainance-free  6 .Ease and safe to operate     2.Description       The SF6 Ring main unit is made up of modular units containing fi xed, disconnectable orwithdrawable metal-enclosed switchgear, using sulphur hexafl uoride (SF6) or vacuum.     The SF6 Ring main unit  are used for the MV section in MV/LV Transformer substations in publicdistribution systems and MV consumer or distribution substations up to 36 kV.     HXGN  series SF6 units are designed for indoor installations. Their compact dimensions are:        a.375 to 1500 mm width
       b.1600 to 2250 mm height
       c. 840 to 1400 mm depth
this makes for easy installation in small rooms or prefabricated substations.Cables are connected via the front.
     All control functions are centralised on a front plate, thus simplifying operation.The units may be equipped with a number of accessories (relays, toroids,instrument transformers, Surge Arrester, control and monitoring, etc.).      3.Normal operating conditions
 Ambient air temperature:
1) less than or equal to 40°C
2) less than or equal to 35°C on average over 24 hours
3) greater or equal to –5°C.
Altitude
1) less than or equal to 1000 m
2) above 1000 m, a derating coeffi cient is applied (please consult us).
Solar radiation
1) no solar radiation infl uence is permitted.
b Ambient air pollution
1) no signifi cant pollution by dust, smoke, corrosive and/or fl ammable gases,
vapours or salt.
 Humidity
1) average relative humidity over a 24 hour period, less than or equal to 95%
2) average relative humidity over a 1 month period, less than or equal to 90%
3) average vapor pressure over a 24 hour period, less than or equal to 2.2 kPa
4) average vapor pressure over a 1 month period, less than or equal to 1.8 kPa.
For these conditions, condensation may occasionally occur. Condensation can be
expected where sudden temperature changes occur in periods of high humidity.
To withstand the effects of high humidity and condensation, such as breakdown of
insulation, please pay attention on Civil Engineering recommendations for design
of the building or housing, by suitable ventilation and installation.   4.Electrical characteristics
 
Rated votlage Ur KV 7.2 12 17.5 24 36
                    Insulation level        
  Insulation  Ud       50/60 Hz, 1 min (kV r ms)  20  28  38  50  70
  Isolation  Ud       50/60 Hz, 1 min (kV r ms)  23  32  45  60  80
  Insulation  Up      1.2/50 μs (kV peak)  60  75  95  125  170
  Isolation  Up      1.2/50 μs (kV peak)  70  85  110  145  195
                   Breaking capacity       
  Transformer off load    A  16 
  Cables off load    A 31.5      50
  Rated current    A 400-630-1250  630-1250
      short-time withstand current  Ik/tk     kA/1s                       25  630-1250  1250
 20       630-1250 
 16       630-1250 
 12.5  400-630-1250  630-1250
    Making capacity (50Hz) Ima       kA                         62.5  630  NA   
 50  630    
 40  630    
 31.25 400-630    
  5.Compartments description a. Busbar compartment     The three insulated busbars are parallel-mounted. Connection is made to the upper pads of the enclosure using a field distribution with integrated captive screws.   b. Switch compartment  This compartment is separated from the busbar compartment and the connection compartment by the enclosure surrounding the switch, the disconnector and the earthing switch.   c. Connection and switch compartment      d. Operating-mechanism cover     These covers contain the various operating functions for the:switch and earthing switch,disconnector(s),Circuit Breaker,contactor and the voltage presence indicator.    6.Our factory view                                  

Contact us if you need more details on Switchgear and Control Panel. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Control Panel、Electrical Control Panel. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Switchboards & Switchgears > Other Switchboards Switchgears