6- 220kV Power,Furnace,Rectifier Transformer Manufacture
6- 220kV Power,Furnace,Rectifier Transformer Manufacture
Payment Type: | L/C,T/T |
---|---|
Min. Order: | 2 Set/Sets |
Delivery Time: | 45 Days |
Packaging: | Wooden Case or Bare |
---|---|
Brand: | SHFE |
Place of Origin: | Shanghai, China (Mainland) |
Supply Ability: | 6 Set/Sets per Month |
Basic Info
Model No.: SF, SZ
Product Description
Specifications 1. Power Transformer
2. Furnace Transformer
3. Rectifier Transformer
4. Distribution Transformer
PRODUCT SCOPE Voltage: Oil type from 6kV-220kV, Dry type from 6kV-35kV Capacity: 100kVA-240MVA APPLICATION Power Transformer Furnace Transformer Rectifier Transformer Distribution Transformer REFERENCES ISO 1461: Hot dip galvanized coatings on fabricated iron and steel articles – Specifications and test methods. IEC 60076: Power transformers. IEC 60044: Instrument transformers. IEC 60296: Specification for unused mineral insulating oil for transformers and Switchgear. IEC 60354: Loading guide for oil – immersed power transformers. IEC 60214: Tap-changers - Part 1: Performance requirements and test methods, Part 2: Application guide. IEC 60512: Connectors for electronic equipment. ROUTINE TEST to IEC 60076 (to be done during acceptance testing at factory) • Measurement of winding resistance • Ratio test • Vector group • Separate source voltage withstand test • Induced over-voltage • Insulation resistance • Oil leakage test on fully assembled transformer for 12 hours • Measurement of impedance voltage • Magnetic balance • Measurement of no-load loss and current • Measurement of load loss (at normal & extreme taps) • Tests on on-load tap-changer • Tests on on-load tap-changer remote control panel • Efficiency at 50%, 75%, 100% loading at unity p.f and rated terminal voltage (Corrected to 75C) • Lightning impulse withstand test Type Tests to IEC 60076 (to be done during acceptance testing at factory) • Temperature rise test – To be performed on one unit during acceptance testing. Lightning Impulse Withstand Test is already listed under Routine Tests as per IEC 60076. Contact us if you need more details on Furnace Transformer. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Rectifier Transformer、Power Transformer. If these products fail to match your need, please contact us and we would like to provide relevant information.
2. Furnace Transformer
3. Rectifier Transformer
4. Distribution Transformer
PRODUCT SCOPE Voltage: Oil type from 6kV-220kV, Dry type from 6kV-35kV Capacity: 100kVA-240MVA APPLICATION Power Transformer Furnace Transformer Rectifier Transformer Distribution Transformer REFERENCES ISO 1461: Hot dip galvanized coatings on fabricated iron and steel articles – Specifications and test methods. IEC 60076: Power transformers. IEC 60044: Instrument transformers. IEC 60296: Specification for unused mineral insulating oil for transformers and Switchgear. IEC 60354: Loading guide for oil – immersed power transformers. IEC 60214: Tap-changers - Part 1: Performance requirements and test methods, Part 2: Application guide. IEC 60512: Connectors for electronic equipment. ROUTINE TEST to IEC 60076 (to be done during acceptance testing at factory) • Measurement of winding resistance • Ratio test • Vector group • Separate source voltage withstand test • Induced over-voltage • Insulation resistance • Oil leakage test on fully assembled transformer for 12 hours • Measurement of impedance voltage • Magnetic balance • Measurement of no-load loss and current • Measurement of load loss (at normal & extreme taps) • Tests on on-load tap-changer • Tests on on-load tap-changer remote control panel • Efficiency at 50%, 75%, 100% loading at unity p.f and rated terminal voltage (Corrected to 75C) • Lightning impulse withstand test Type Tests to IEC 60076 (to be done during acceptance testing at factory) • Temperature rise test – To be performed on one unit during acceptance testing. Lightning Impulse Withstand Test is already listed under Routine Tests as per IEC 60076. Contact us if you need more details on Furnace Transformer. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Rectifier Transformer、Power Transformer. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : Distribution Transformers > Other Distribution Transformers
Premium Related Products
Other Products
Hot Products
Moulded Case Circuit Breaker, MCCBIntelligent Universal Circuit Breaker(ACB)3000kg Block ice machineAir load break switchVacuum circuit breaker 15kvMetal clad cubicle switchboardMedium voltage metal clad 15 kv switchgearLow voltage generator paralleling switchgearMeta-clad withdrawable type ht switchgearGTM2L 4 pole earth leakage circuit breakerThree phase copper winding wound core low loss 35kv 6.3mva transformerGTM2L earth leakage circuit breakerThree phase oil immersed type copper winding wound core low loss 15 mva 20kv transformer11kv 415v dry type power transformerOil immersed type 400kv power transformerFlake ice machine for Cocktail